logo
NANTONG HWATEK WIRES AND CABLE CO.,LTD.

HWATEK-DRADEN EN KABELco., LTD.

Thuis ProductenEV ladende Kabel

TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles

Certificaat
China NANTONG HWATEK WIRES AND CABLE CO.,LTD. certificaten
China NANTONG HWATEK WIRES AND CABLE CO.,LTD. certificaten
dank u zeer voor uw snelle reactie. Uw professionele kabeloplossing helpt me uit, is de Kabelkwaliteit zeer goed. Het past onze schakelaars

—— Gonalze

Uw productenkwaliteit voorbij mijn veronderstelt, waardeer ik hoogst uw grote steun, voortaan heeft de Hoop betere en diepere samenwerking.

—— Bharath

Ik ben online Chatten Nu

TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles

TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles

Grote Afbeelding :  TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles

Productdetails:
Certificering: ISO9001, CCC, RoHS
Betalen & Verzenden Algemene voorwaarden:
Min. bestelaantal: 3.000
Prijs: 0.5
Gedetailleerde productomschrijving
Geleidingsmateriaal: Koper Schede materiaal: PVC
Isolatiemateriaal: TPE Materiële vorm: Ronde draad
Nominale spanning: AC450/750V Nominale temperatuur: -40 ~ +90 ° C
Type geleider: Gestrand kaal of gekopper Schede materiaal: TPU
Minimale buigradius: 5xod Brandbaarheidstest: Iec60332-1
Draadspecificaties: 3 × 2.5+2 × 0,75, 3 × 4+2 × 0,75, 3 × 6+2 × 0,75, 5 × 2,5+2 × 0,75, 5 × 4+2 × 0,75, 5 × 6+2 × 0,75, Verwijzingsstroom: 18a, 25a, 34a, 50a, 67a
Diameter ongeschreven: 12,7 mm, 14,4 mm, 16,3 mm, 15,3 mm, 17,8 mm, 19,8 mm, 22,9 mm, 27,5 mm Hoeveelheid per rol: 305m, 610m of als verzoek
Transportpakket: Gerold in haspels, verpakt in pallets
Markeren:

IEC60332-1 Flammability Test EV Charging Cable

,

Minimum Bending Radius 5xOD Electric Vehicle Charging Cable

,

305m 610m Length EV Power Cable

TPE Insulated AC & DC 450V 750V EV Charging Power Cable
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 0
Certification
General Administration of Quality Supervision, Inspection and Quarantine
Certificate No. Product Types
CQC16011142377 EV-(R)SS, EV-(R)SSPS, EV-(R)S90S90, EV-(R)S90S90PS90, EV-(R)S90U, EV-(R)S90S90PU-450/750V
Structure Diagram
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 1
Reference standard: GB/T 33594-2017
Product Specifications
AC Types: EV-(R)S90U, EV-(R)S90S90PU-450/750V 1.0-70(2-5Cores)+0.5-0.75(P/P2)(1-10Cores)
Construction Details
  • Rated temperature: -40°C to +90°C
  • Rated voltage: AC 450/750V
  • Conductor: Stranded bare or tinned copper
  • Insulation material: TPE
  • Sheath material: TPU
  • Flexible construction with resistance to cold, oil (11 types), ozone, abrasion, UV, external pressure and thermal stress
  • Passes IEC60332-1 flammability test
  • Minimum bending radius: 5xOD
  • Easy installation
Applications: Suitable for all types of electric vehicles, charging piles, power stations, and charging stations.
Structural Parameters
Category Wire Specifications Reference Current (A) Diameter Unshielded (mm)
TPE | PU 3×2.5+2×0.75 18 12.7 | 11.1
3×4+2×0.75 25 14.4 | 12.8
3×6+2×0.75 34 16.3 | 14.5
5×2.5+2×0.75 18 15.3 | 13.7
5×4+2×0.75 25 17.8 | 16.0
5×6+2×0.75 34 19.8 | 17.8
5×10+2×0.75 50 22.9 | 20.7
5×16+2×0.75 67 27.5 | 25.1
Notes:
  1. Detailed dimensions are subject to product specifications
  2. Other specifications can be custom designed according to customer requirements
  3. Standard sheath colors are black or orange, with custom colors available
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 2
Company Profile

Founded in 2004 with $9 million USD capital investment, our headquarters factory in Kunshan covers 14,980 square meters.

In 2020, we established our Nantong facility with 100 million RMB capital investment covering 34,000 square meters.

Certifications: ISO9001, ISO14001, IATF16949, ISO13485

Product certifications: CCC, UL, CUL, CE, CSA, ETL

Management principles: HONESTY, INNOVATION, ENVIRONMENTAL PROTECTION

Certificates
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 3
Production Process
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 4
Shipping
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 5
Frequently Asked Questions
Q: What products do you supply?
A: We produce consumer electronics wires, hook-up wires, industrial cables, robot cables, EV charging cables, and new/green energy cables.
Q: What certifications do you have?
A: Our products have UL, CE, 3C, Dekra, CQC, TUV, Rohs, Reach, and ETL certifications.
Q: Can we get samples before ordering?
A: Yes, we can arrange samples for evaluation.
Q: What is your production lead time?
A: Standard lead time is 2-3 weeks, extending to 5-6 weeks during peak seasons.
Q: How do you ensure product quality?
A: We conduct pre-production sampling and final inspection before shipment.
Major Customers
TPE Insulated EV Charging Cable with IEC60332-1 Flammability Test and Minimum Bending Radius 5xOD for Electric Vehicles 6

Contactgegevens
NANTONG HWATEK WIRES AND CABLE CO.,LTD.

Contactpersoon: Jimmy Wang

Tel.: 17715039722

Direct Stuur uw aanvraag naar ons (0 / 3000)